Application of Digital Ultrasonic Flaw Detector in Weld Inspection
One. Preparation before flaw detection Next page
Phlizon is a new high-tech enterprise, specializing in research, production, sales services of LED Grow Light.The headquarters is located in Huilongda Industrial Park, Shilongzai ,Shiyan Street, Baoan District, Shenzhen, China.So far we have overseas warehouses in the United States, Germany, the United Kingdom, and Spain.we strive to provide convenient and highly efficient solution services.
Adopts Samsung LED 5630 as light sources, which has the advantages of high performance, low energy consumption and stability.
Input voltage:AC100-240V,easy to use, safe and suitable for any country.
LED Lifespan is reach up to 50,000 hours.
Suitable for all kinds of plant growth, flowering and yield
Safe and environmental protection, free from pollution and harmful substances
Features:
Seeding,Rooting,Breeding,Flowering and Fruiting period
Cautions
1.This light is not waterproof, do not spray water
2.Never touch and hit the Light while it is working.
3.Lighting work environment is -20 ~ 40 °C, 45% ~ 95% RH.
4. Please cut off the power when there is a lightning strike.
5. Make sure that the mounting position can withstand 10 times the weight of the light.
PH Linear Series,Quantum Board Grow Light,Quantum Board Grow Light Kits,Led Quantum Board Grow Light,200W Quantum Board Grow Light Shenzhen Phlizon Technology Co.,Ltd. , https://www.szledaquariumlighting.com
1.UTD600 digital ultrasonic flaw detector 2. Transverse wave oblique probe: 5M13×13K2
3. Standard test blocks: CSK-IB, CSK-3A
4.30mm thick steel plate butt weld 5.DAC parameters:
(1) DAC points: 4 points of d=5, 10, 15, 20 (mm) (2) Discontinued line offset: +5dB
(3) Quantitative line offset: -3dB
(4) Evaluation line offset: -9dB
6. Coupling agent (such as: oil, etc.)
two. Detection surface selection
Weld side
three. Boot
1. Connect the probe to the ultrasonic flaw detector 2. Open the panel switch , power on self-test, about 5 seconds into the flaw detection interface.
3. Quick basic settings:
(1) Press The key causes the five function main menus “Basicâ€, “Transceiverâ€, “Gateâ€, “Channel†and “Probe†to be displayed at the bottom of the screen.
(2) Press the “F1†key to enter the “Basic†function group, adjust the “Detection Range†in the “Basic†function to “150â€, adjust the “Material Sound Velocity†to “3230â€, and “Pulse Shiftâ€. Adjust to "0.0" and adjust "Probe Zero" to "0.00".
(3) Press the F2 key to enter the “Transceiver†function group, adjust the “Probe mode†in the “Transceiver†function to “Single crystalâ€, and adjust “Echo suppression†to “0%â€.
(4) Press the F3 key to enter the “gate†function group, set the “gate alarm†to “offâ€, adjust the “gate width†to “20.0â€, and adjust the “gate height†to “50%â€. (The adjustment of this article can be based on the user's habits).
(5) Press the F4 key to enter the “Channel†function group, and adjust the “Flaw Detection Channel†to the desired channel with no stored curve, such as “No.1â€. At this time, “Setting Out†and “Setting Save†And "Setting Delete" are displayed as "Off" by default.
(6) Press the F5 key to enter the “Probe†function group, adjust the “Probe K value†to “0.00â€, adjust the “Workpiece thickness†to “50.0â€, and adjust the “Probe front edge†to “0.00â€. The “Scale Method†is adjusted to “Sound Pathâ€.
(7) Click The key causes the five function main menus “Gainâ€, “DAC1â€, “DAC2â€, “AVG1†and “AVG2†to be displayed at the bottom of the screen.
(8) Press the F1 key to enter the “Gain†function group and adjust all the contents to “Offâ€.
(9) Press the F2 key to enter the “DAC1†function group, turn “DAC Curve†to “Onâ€, adjust “DAC Calibration Point†to “0â€, and “Display Calibration†to “Onâ€.
At this time, the “DAC2†corresponding to the F3 button, the “AVG1†corresponding to the F4 button, and the “AVG2†corresponding to the F5 button do not need to be set; if you press again at this time The keys, the bottom of the screen display the "B scan", "screen saver", "storage", "setup" and "advanced" five main menus, the traditional method of calibrating the oblique probe, these five menus do not need to do any settings.
Note: After entering each function, use the “direction keys†to move the bright bar to the item you want to adjust, and use the “+†or “-†key to adjust the value. The basic settings have been adjusted.
100-277v/200-480v for industrial planting
Higher PPFD value per unit area
Full Spectrum Grow Light mimics natural sunlight for different period of growth
Passive heat sink and die casting aluminum shell
Aluminum body for a good heat-dissipation
Elegant appearance
Easy to install by minute
More convenient and simple for maintenance
Energy saving,environmental friendly
3-5 Year warranty
Applications
Hydroponics,Horticulture,Agriculture and Greenhouse
Locations:Farm,Exhibition,Garden,Home,Urban,Bonsai,and University Lab
Growth of Fruits,Vegetables,Flowers and so on
Phlizon is the manufacturer factory and we sell our products at a low price directly, besides all our Power supply, Fans and wire all are Fire-resistant material,won't catch fire.
We currently have warehouses in the UK, USA, Canada,Spain, and Australia,and we are working on opening more warehouses in other countries to shorten our delivery time.
We have strong OEM/ODM capabilities, with experienced teams, full post-sales support and an established quality control system.
We promise to provide high-quality products with competitive prices, fast delivery, and responsive services for our clients.