Decoration acceptance standard decoration acceptance considerations

Acceptance is an indispensable part of the renovation and is also a very important part. The decoration inspection is a supervision and inspection of the quality of the entire renovation project. In this process, the problems existing after the completion of the renovation are discovered and dealt with in a timely manner. What are the decoration acceptance standards ? Next Xiaobian gave everyone about the decoration acceptance standards .

First, the decoration acceptance standards - sanitary appliances and pipe installation acceptance standards

1. The types, specifications and colors of sanitary appliances should meet the requirements of design and households; the quality of products such as pipes and pipe fittings should comply with current standards.

2. The pipeline shall be installed horizontally and vertically, laid firmly, and the slope shall meet the requirements; the switch and faucet shall be installed in a square, flexible and convenient to use, and the tube shall be brushed and rust-proof paint, and the dark pipe shall be used to remove the lacquer.

3. The water pipelines and accessories are tightly connected and there is no leakage through the water pressure test.

4. The drainage pipeline shall be free from falling, non-clogging, and no leakage. The floor drain shall be slightly lower than the ground.

5. Sanitary appliances are installed firmly, with good appearance and no damage.

Second, decoration acceptance standards - electrical engineering acceptance standards

1. The electrical product materials must be qualified products that meet the relevant standards, and the electrical construction personnel should hold certificates.

2. The electrical wiring should adopt dark pipe laying. The wire should not have knots and kinks in the pipe. It is forbidden to directly bury the wire in the plastering layer.

3, to ensure that the "fire line into the switch, the zero line into the lamp," when the socket connection should comply with "left zero right fire, grounding on the" provisions.

4. The switches and sockets are securely installed, the position is correct, the cover is positive, the surface is clean, and it is close to the wall. There is no space around and the height of the same room switch or socket is the same.

5. After the completion of the electrical construction, the necessary experiments should be carried out, such as: electrical power, lighting test, switch test control and so on.

6. When the project is completed, it is necessary to provide the household with a schematic diagram of the wiring work, indicating the direction of the wire and the pipe.

Summary: The relevant knowledge about the decoration acceptance standards is introduced here. For more information, you can pay attention to this site information .

Construction acceptance switch socket decoration design electrical paint decoration acceptance standards